email:abbdrive88@gmail.com
Call us 24/7+86 15396212224
Call us 24/7+86 15396212224

Vibro-Meter VM600 MPC4 Mechanical Protection Card

Key Features and Benefits

– From the Vibro-Meter® product family

– Continuously on-line machinery protection card

– Real-time measurement and monitoring with state-of-the-art DSP technology

– 4 dynamic signal channels and 2 RPM (speed) channels, all individually programmable

– Programmable broadband and narrowband filters

– Simultaneous monitoring of amplitude and phase in sequential tracking mode

– Programmable alarms, hazards and defined setpoints

– Adaptive alarm and hazard levels

– Front panel BNC connector for easy analysis of buffered “raw” transducer signals

– Front panel LEDs to indicate status and alarms

Key Benefits and Features (continued)

– Integrated power supply for sensors and signal conditioners such as IEPE accelerometers and proximity measurement systems

– Real-time plug-in cards (hot-swappable)

– Available in “standard”, “circuit independent” and “safety” (SIL) versions

Applications

– Mechanical protection and/or basic condition monitoring

Description

MPC4 Card

The MPC4 Machine Protection Card is the centerpiece of the VM600 series of Machine Protection Systems (MPS) from Meggitt’s Vibrometer® product line. The card is extremely versatile, capable of measuring and monitoring up to four dynamic signal inputs and two velocity inputs simultaneously.

The dynamic signal inputs are fully programmable and can accept the following signals

acceleration, velocity and displacement (proximity) signals. On-board multi-channel processing allows measurement of a wide range of physical parameters including relative and absolute vibration, Smax, eccentricity, thrust position, absolute and differential case expansion, displacement and dynamic pressure.

Digital processing includes digital filtering, integration or differentiation (if required), www.ge-drive.com rectification (RMS, average, true peak, or true peak-to-peak), order tracking (amplitude and phase), and measurement of transducer-to-target clearance.

The speed (tachometer) input accepts signals from a variety of speed sensors, including systems based on proximity probes, magnetic pulse pickup sensors, or TTL signals. Fractional tachometer ratios are also supported.

Configurations can be expressed in metric or imperial units. Alarm and hazard setpoints are fully programmable Alarm time delay, hysteresis and latching, hysteresis and latching. Alarm and hazard levels can also be adjusted based on speed or any external information. The alarm and hazard levels can also be adjusted based on speed or any external information.

Each alarm level has an internal digital output (on the appropriate IOC4T I/O card). These alarm signals can drive the four local relays on the IOC4T card, and/or relays on optional relay cards such as the RLC16 or IRC4 via the VM600 rack’s raw bus or open collector (OC) bus.

Processed dynamic (vibration) and velocity signals are available as analog outputs at the rear of the rack (on the front panel of the IOC4T). Voltage signals (0 to 10 V) and current signals (4 to 20 mA) are available.

The MPC4 performs self-tests and diagnostic procedures at power-up. In addition, the card’s built-in “OK system” continuously monitors the signal level provided by the measurement chain (sensors and/or signal conditioners) and indicates any problems caused by broken transmission lines, faulty sensors or signal conditioners.

An LED on the front panel of the MPC4 indicates whether a processing or hardware error has occurred. A further six LEDs, one for each input channel, indicate whether the OK system has detected a fault and whether an alarm has occurred on the channel.

There are three versions of the MPC4 card: the “standard” version, the “circuit independent” version, and the “safe” (SIL) version, all of which use the appropriate IOC4T input /output cards as card pairs.

Different versions of the MPC4 card

There are different versions of the MPC4 card, including “Standard”, “Circuit Independent” and “Secure” (SIL) versions. In addition, some versions have a conformal coating applied to the card’s circuitry to provide additional environmental protection against chemicals, dust, moisture and temperature extremes.

Both the “Standard” version and the “Safety” (SIL) version of the MPC4 card are certified to IEC 61508 and ISO 13849 for use in functional safety environments such as SIL 1 according to IEC 61508 and ISO 13849-1 for PL c.

The “standard” MPC4 card is the original version and supports all functions and processing modes.

The “standard” MPC4 is suitable for safety systems using the VM600 rack. Safety systems. The “standard” MPC4 card is the original version and supports all functions and processing modes. The “Standard” MPC4 card is the original version and supports all functions and processing modes. card pairs and the RLC16 relay card. It has a VME-compatible slave interface so that it can be configured via software via VME when VME is available. It is software configurable via VME when acting as a rack controller in a VM600 rack. It is also software configurable via RS-232 (on the front panel of the card).

The ‘Secure’ (SIL) MPC4 card (MPC4SIL) has been developed to provide a wider range of installation options. Specifically, the VM600 rack also contains condition monitoring cards (e.g. XMx16) and relay cards (e.g. IRC4). In order to certify the security of these configurations, it is necessary to ensure that the MPC4SIL is isolated from the other cards in the VM600 chassis so that its configuration is not inadvertently modified.

As such, the MPC4SIL card does not include a VME-compatible slave interface, does not support tachometer (speed) channels, and does not provide all of the signal processing features of the “standard” MPC4 card (see “Additional Specifications – ‘Standard’ Only” on page 9). “ and “Circuit Independent” MPC4 cards).

Isolation of MPS and CMS

The VM600 rack, Mechanical Protection Card, Condition Monitoring Card and associated software have been designed to comply with the API670 standard for the isolation of the Mechanical Protection System (MPS) and Condition Monitoring System (CMS) to ensure that the functionality of the MPS is not dependent on, or in any way affected by, the operation of the CMS.

Therefore, whilst Mechanical Protection and Condition Monitoring cards can easily share sensor signals from the measurement chain, in a VM600 rack, the MPC4/IOC4T card pair does not share any communication buses with the XMx16/XIO16T Condition Monitoring card pair and the MPC4/IOC4T card pair is configured and operated using the VM600 MPSx software (whereas the XMx16/XIO16T card pair is configured and operated using the VM600 MPSx software (whereas the XMx16/XIO16T card pair is configured and operated using the VM600 MPSx software). XIO16T card pair is configured and operated using VibroSight® software).

Application Information

The MPC4. when used in pairs with the IOC4T I/O cards, is ideally suited for machinery monitoring and protection in a variety of industrial applications.

Hitachi Energy 560NMD01 Managed Layer 2 Switch

Applications

The 560NMD01 Top Hat DIN-Rail Appliance is a managed Layer 2 switch.

It provides four Fast Ethernet RJ45 ports with automatic MDI/X (Automatic Cross Detection and Correction) and a 2-wire SDSL interface.

The SDSL interface can be used to connect sites with distances of up to 20 km (copper cable, 0.8 mm diameter).

Thanks to the (fast) Spanning Tree Protocol, the switch enables a redundant topology.

For documentation purposes, Ethernet ports are labelled with numbers 1-4. There are no special uplink ports. All ports are functionally identical.

The SDSL ports are externally connected via backplane or expansion connectors. The connection (link) and speed status of all Ethernet and SDSL ports is indicated by LEDs on the front panel.

The switch “learns” Ethernet addresses by analysing received frames.

The addresses learned in this way are stored in the address table (up to 2048 entries) and are used to forward the frames to the correct interface.

Frames are forwarded to all interfaces only if they are received with a wide or multicast address, or if the destination address is not found in the address table.

If an entry in the address table is not acknowledged by the corresponding www.ge-drive.com received frame, it is deleted after a maximum of 304 seconds (default).

IEEE 802.1Q-compliant VLAN configuration is supported. Frames can be transparently forwarded or assigned to (access or trunk) VLANs.

The switch can support quality of service if IEEE 802.1p-compliant frame formats are used. The switch can divide outbound frames into up to four priority-controlled queues.

The device has a wide-range power supply, requiring a voltage between 24 and 60 V. The switch can be used with a wide range of power supplies.

The Ethernet interface, SDSL, RS232 (Con 0) and the expansion bus interface (Ext) can be plugged in during operation (hot-swap).

Connectors and indicators

The 560NMD01 device provides four equivalent Ethernet interfaces with RJ-45 connectors, an SDSL interface and an RS232 interface that are

for configuration and transfer of serial data. Each RJ-45 port can be connected via Cat.3 (10Mbps) or Cat.5 (100Mbps) network cable.

for internal communications up to 100 metres. Support for MDI/X means that crossover Ethernet cables are not required.

The SDSL interface can be connected via a two-wire copper cable. The maximum connection distance is 20 kilometres using a 0.8 mm diameter copper cable with a transmission rate of 192 kbps.

Depending on the distance, the transmission rate can be increased to a maximum of 11 Mbps.

The status of all interfaces can be monitored by two LEDs. For Ethernet interfaces, these are located on the lower and upper part of the RJ45 socket.

MOOG L180 Programmable Servo Driver

The L180 servo drive is used to control MOOG brushless servo motors.

These are three-phase motors with 8 or 12 poles (4 or 6 pole pairs) with bipolar resolvers.

The L180 servo drive is fully digital. The high-performance torque and speed control meets all requirements for fast response and high control accuracy.

The digital control allows full diagnostics, motor parameter adjustment, data and fault detection using a PC-based graphical user interface (GUI).

The L180 servo drive features the following:

Power supply

– Single-axis unit that includes a regenerative module to www.ge-drive.com minimise wiring and space requirements.

– 230 V three-phase or single-phase.

– Optional: External filter in the power supply is CE compliant.

– The drive is designed to Protective Extra Low Voltage (PELV) standards. An autotransformer is sufficient for the mains input.

Power Driver

– Galvanic isolation between control and power electronics.

– IGBT output stage.

– Digital PWM current loop provides low ripple motor current and high motor efficiency.

Digital Controller

– Fully digital servo drive for brushless motors with resolver.

– Easy software download via RS232 serial connection.

– Temperature regulated fan cooling.

– Multi-loop control (torque and speed).

– Sine current output ensures smooth torque and performance at low speeds.

– 7-segment status indicator for diagnostic display.

User Inputs

– ±10VDC differential analogue input for speed or current commands.

– RS232 serial port.

– Limit switches for bi-directional overrun protection.

– Optional external 24VDC power supply for control and interface boards in the event of a mains power failure.

User Outputs

– Programmable incremental encoder analogue output with 1 to 2048 ppr resolution (extrapolated), differential RS 422 line driver output.

– Programmable supervisory relays to indicate ready, alarm or enabled status.

Protection Features

– The power stage is short-circuit and thermal protected.

– Motor thermal protection through I²t limiting and thermistors.

– Detects resolver faults and motor wiring faults.

Related Product Recommendations:

1769-OF8C Analog Output Module

ILX56-MM Message Manager for Industrial Communications

BSFC-02C Charge Controller Universal Brake Chopper

1769-OF2 Analog Output Module

5X00419G01 Ethernet Link Controller

1769-PB4 Power Module

IC660TBD025 GeniusI/O Terminal Assembly Module

BSFC-01C Charge Controller Board SP Kit Gate Driver Boards

IC660TBD024K GeniusI/O Terminal Assembly Module

Search for products

Back to Top
Product has been added to your cart