email:abbdrive88@gmail.com
Call us 24/7+86 15396212224
Call us 24/7+86 15396212224

Eaton MOPEG240C Module Motor Operator Module

About the MOPEG240C

The MOPEG240C module is a motor operator module manufactured by Eaton Corporation. The module is designed for use with Eaton’s G-Series E-frame line of

of EGB, EGE, EHC, EGS and EGH circuit breakers. It is rated for 100 to 220 volts AC or 100 to 220 volts DC operating voltage,

1 amp inrush current and 50 to 60 Hz operating frequency. The Motor Operator Module allows the user to remotely or locally switch the ON, OFF and RESET functions of the circuit breaker remotely or locally.

Both modes of operation support manual and automatic control of the unit.

In manual mode, the operation keys included with the www.ge-drive.com MOPEG240C Motor Operator Module can be used to locally open, close, or reset circuit breaker contacts via the locking holes.

Remote control of the MOPEG240C Motor Operator Module involves the use of its built-in motor and cam drive mechanism to adjust the assembly that operates the circuit breaker handle.

The unit shall be mounted on the front cover of the circuit breaker within its dimensions.

The internal limit switches and relays on the unit are tasked with controlling motor operation by ensuring that the circuit breaker handle only moves within a defined range.

The Eaton MOPEG240C motor operator module can be manually tripped via its push-button trip button.

It contains a pull-out locking mechanism for locking the circuit breaker handle in the OFF position with a padlock and can be used for standard load transfer switching applications.

The status of the unit can be seen by the status indicator on the front cover.

MOPEG240C Technical Description

The Eaton MOPEG240C motor operator operates at 1 amp and 100-220 volts DC. It has a pushbutton trip button and a manual operation key.

Eaton HVX003A2-4A1B1 AC Drive

DESCRIPTION

Eaton – AC Drive, Inverter, 3HP, 5.6A, 380-500VAC HVX 9000

About the HVX003A2-4A1B1

The Allen-Bradley HVX003A2-4A1B1 drive is part of the HVX 9000 AF series.

It has a nominal 3-phase input voltage of 480V and can operate over a range of 380V to 500V.

The output voltage can be adjusted from 0 to the input voltage level. Its power rating is approximately 3HP or 2.2kW.

The input frequency varies from 45 to 66Hz with a default frequency of 50-60Hz.

The output frequency is programmable from 0-320Hz with a frequency resolution of 0.01 Hz.

The enclosure for this drive is NEMA Type 12. The HVX003A2-4A1B1 has an ambient operating temperature of -10 to 40 degrees Celsius.

Storage temperature is between -40 and 70 www.ge-drive.com degrees Celsius with up to 95% relative humidity, non-condensing and non-corrosive.

Operating vibration up to 1G at 15.8-150 Hz and altitude limits up to 1000 metres (3300 feet).

In addition to this, the HVX003A2-4A1B1 will derate at 1% of the drive’s rated current.

The HVX003A2-4A1B1 requires the use of 75°C or higher heat resistant copper cable.

The maximum cable length should be approximately 984 feet (300 metres). The motor cable should be routed through other cables at a 90 degree angle.

This type of drive uses specific UL cables to ensure cable compatibility with the drive.

The HVX003A2-4A1B1 rack size uses FR4 cable and 4.8-5.6 A for NEC input current.

The power and ground cables have similar wire sizes with a value of 14. The power terminals have terminal sizes of 16-12. The same is true for the ground terminals.

The approximate dimensions of the HVX003A2-4A1B1 are 327 x 128 x 190 mm (12.9 x 5 x 7.5 in.) with a mass of 5 kg (11 lb).

Eaton Inverter Drive DG1-34170FB-C54C

Description:

The DG1-34170FB-C54C drive is a variable frequency drive from Eaton.

The DG1-34170FB-C54C drive is designed to operate at 380 to 480 volts AC.

About the DG1-34170FB-C54C

The DG1-34170FB-C54C drive is a variable frequency drive. It is designed and manufactured by Eaton Corporation.

The dimensions of the drive are 888 x 290 x 34 mm. The drive www.ge-drive.com enclosure is rated IP 54 or NEMA 12.The DG1-34170FB-C54C drive supports four-quadrant operation.

Communication interfaces available on the drive include Ethernet and RS-485 serial interfaces.

Communication protocols supported by the drive include BACNet, ProfiBus, DeviceNet, Modbus, CAN, and TCP/IP protocols.

The number of digital inputs on the drive is 8. The number of digital outputs is 1. The number of analogue inputs on the drive is 2.

The number of analogue outputs is 2. The DG1-34170FB-C54C drive is designed to operate at 50 to 60 Hz at 380 to 480 volts AC (3 phase) supply voltage.

The maximum output frequency is 400 Hz and the maximum output voltage is 480 volts AC. The nominal output current is 205 amperes.

The maximum output of the secondary load is 110 kW at rated output voltage. The maximum output for linear loads is 180 kW at rated output voltage.

The minimum ambient operating temperature for the DG1-34170FB-C54C drive is -10 degrees Celsius and the maximum ambient operating temperature for the drive is 50 degrees Celsius.

There are two expansion slots on the DG1-34170FB-C54C drive. The external control voltage is 24 volts DC and the maximum current input is 250 mA.

The drive has a rack size of FS5.The drive is equipped with radio interference suppression filters, PCB protection, a multi-line graphic display, a braking chopper and a DC connection choke.

A temperature controlled fan is also provided on the drive.

Eaton DPM-MC2 Communication Card

Aims and purposes of this document

The purpose of this document is to provide a reference for connecting, commissioning and operating the DPM-MC2 Communication Card.

Use of the card

The DPM-MC2 card can only be used in MICRO PANEL MC2 series devices equipped with the corresponding slot.

The DPM-MC2 card is a PROFIBUS master. The development is based on the EN50170 standard.

The card can only be mounted and dismounted when the device is powered off.

Function and control indicators

Connector assignment

The plug connectors and connector assignment comply with the Profibus standard (EN50170). Only the transceiver signals and the power terminals for line termination are provided.

The power supply terminals DGND (0V, pin 5) and VP (+5V, pin 6) are only intended for powering the cable terminals (terminals) and must not be used for any other purpose. the CNTR-P signal (pin 4) is used in conjunction with a repeater.

Bus segments must be terminated at both ends.

No more than 2 bus terminals must be activated per bus segment!

At least one of the two bus terminals must be powered www.ge-drive.com by the bus station!

Maintenance, repair, disposal

Maintenance

Repairs can only be carried out by the manufacturer or an authorized service center. In this case, please contact your local MICRO PANEL dealer or Micro Innovation’s technical support department.

The warranty does not apply if any modifications are made to the device that are not described in this document.

Shipping

The original packaging must be used when transporting the device.

Disposal

Memory cards that are no longer in use must be disposed of properly or returned to the manufacturer or seller for proper disposal.