Description
The AC30 variable speed drive has been designed to provide users with exceptional levels of motor control, from simple open-loop pumps and fans through to closed-loop process line applications.
The AC30 combines advanced performance with exceptional ease of use, making even the most complex applications simple to achieve.
Working with the five principles of Flexibility, Simplicity, Reliability, Connectivity and Capability our engineers have created a product focussed on making the benefits of quality motor control available to every business.
Parker provides easy to use software tools for all levels of experience; enabling users to address any application. Simple applications can be setup in seconds and more complex applications can be configured in the simplest and most logical way.
Programming can be via the keypad, DSELite, Parker Drive QuickTool software or the Codysys based Parker Developer with full IEC 61131 PLC Functionality.
The AC30 provides users with access to a large library of application macros and worked examples. While users are free to develop their own applications, they can also save time and development cost by accessing and customising examples of completed solutions.
To enable connectivity into a wide range of automation systems the AC30 features Profinet and Ethernet IP through dual Ethernet ports, as well as Modbus TCP IP with client and server functionality.
That makes the AC30 series compatible with more than 80 percent of automation architecture; there is no need for expensive add-ons or upgrade modules.
The Ethernet protocols also provide potential for intelligent data analytics and connection to external servers – opening up links to the cloud or big data
functionality.
So whether for standalone use or for integration into a complex automation system, the AC30 offers an easy to use solution for both simple and advanced motor control applications.
Technical Characteristics – Overview
Designed with you in mind
Flexibility
A fully featured list of standard functionality along with the use of common control and option modules allows users to put the drive to work in many different open- or closed-loop applications.
Simplicity
From the clear and concise backlit LCD display to the easy to use programming software, AC30 has been engineered to make the process of commissioning, operating and maintaining the drive as easy as possible.
Reliability
Parker engineers have taken every possible step to reduce the likelihood of problems occurring, including a number of features in the AC30 that will ensure any loss of productivity is minimised and production restarted as safely and as soon as possible.
Connectivity
Its flexible and highly modular construction enables a wide range of communications and I/O modules to be easily added as required. This enables AC30 to be used in advanced applications including multiple drive configurations.
Capability
Integrated macros for a range of applications and PLC functionality enable more capable users to create sophisticated control that would previously have required a separate PLC. The AC30 can be integrated into even the most complex systems.
Compact footprint, chassis or through-panel mounting
• Multi-position feet with keyhole slots for ease of mounting
• Reduced heat radiation allows side-by-side mounting
Engineered cooling improves reliability
• Intelligent design minimises force ventilation requirements
• Removable fan improves maintainability
• Isolated power stack cooling path reduces contamination of control electronics
Unobstructed access to power and dynamic brake terminals
• Terminal covers removable with drive in-situ
• Dynamic brake switch fitted as standard
• Easy access to DC Bus connections
Suitable for harsh environments
• AC30 is conformally coated as standard and meets the www.ge-drive.com requirements of environment classes 3C1, 3C2 (all defined substances) plus 3C3 and 3C4 for Hydrogen Sulphide (H2S)
• DNV marine / offshore approval
Suited to all environments
• Internal EMC filter options up to C2 1st environment for use in commercial buildings
• CE marked to EN61800-5-1 and NRTL listed to UL508C and C22.2#14
• DC link chokes above 2.2 kW reduce harmonics to below IEC/ EN61000-3-12 limits
Expandable I/O capabilities
• A range of option modules expand AC30 to accommodate application specific I/O
• High-performance, closed-loop control with pulse encoder or resolver feedback module
• Spring clamp terminals reduce installation time and risk of loose connections