ProSoft MVI56-MDA4 Analyzer Master Module
MDA Scientific CM4 Gas
Analyzer Main Module
MVI56-MDA4
The MVI56 MDA Scientific CM4 Gas Analyzer Master Module allows Rockwell Automation ControlLogix processors to easily interface with MDA Scientific CM4 gas monitoring hardware as a host.
Features and Benefits
The MVI56-MDA4 module is an input/output module between the CM4 network and the Rockwell Automation backplane.Data transfer from the ControlLogix processor is asynchronous with operation on the CM4 network.
The 5000 words of register space in the module are used to exchange data www.ge-drive.com between the processor and the CM4 network.
General Specifications
– Single slot – 1756 backplane compatible
– Module is considered an input/output module with access to processor memory for data transfer between processor and module
– Ladder logic is used to transfer data between the module and the processor. Example ladder diagram files are included.
– Configuration data from a configuration text file downloaded to the module.
– Local or remote rack
Functional Specifications
Some general specifications include
– Supports storage and transfer of up to 5000 registers. File
– Two CM4 master ports.
– Configurable parameters include
o Baud rate 110 to 115.200
o Parity None, Odd, Even
o Data bits 5 to 8
o Stop bits 1 or 2
o RTS on and off timing 0 to 65535 milliseconds
o Use CTS modem line Yes or No
o Response timeout 0 to 65535 milliseconds
o Number of slaves 1 to 10
o Simplified data structure yes/no
o Protocol version 1 or 2
o Polling delay 0 to 65535 milliseconds.
Ports configured as virtual CM4 masters on the MVI56-MDA4 module will actively issue CM4 commands to other nodes on the CM4 network. Issues CM4 commands to other nodes on the CM4 network. Supports four read and five
Four read commands and five write commands are supported.
The MDA-4 product includes the following standard features Features:
– Two fully configurable serial ports, each capable of supporting CM4 master functions.
– Supports up to 10 CM4 units per serial port, for a total of 10 CM4 units per module, for a total of 10 units per module.
– Supports movement of binary, integer, ASCII, and floating-point data types Floating-point data type
– Memory maps are predefined in the module to facilitate ladder program execution.
– RS-485 connections on each port can be directly connected to the CM4 unit.
– Software Configuration (from processor ladder logic)
o Slave Address: 0 through 31
o Commands: select commands to be executed
– CM4 command codes are supported:
o Read Command
o 0x30 Get System Information
o 0x31 Get device status
o 0x36 Get alarm history
o 0x37 Get current point status
o Write command
o 0x51 Reset fault or alarm
o 0x52 Set key code
o 0x53 Lock keypad
o 0x60 End point lock
o 0x61 Start point lockout
– Returning the ladder processor’s mode of operation
– Return ladder processor error code