email:abbdrive88@gmail.com
Call us 24/7+86 15396212224
Call us 24/7+86 15396212224

Vibro-Meter RLC16 Relay card Relay card

Features

” From the Vibro-Meter® product family

” Relay card with screw terminal block

” 16 relays with changeover contacts

” Relay-driven inverted logic (jumper selectable)

” Low contact resistance

” Low capacitance

” High throughput power

” Real-time board insertion and removal (hot-swappable)

” EU EMC compliance

Description of the RLC16 Relay Card

The RLC16 relay card is designed for use in Meggitt Sensing Systems’ VM600 Series Vibrometer® product line for mechanical protection systems as well as condition and performance monitoring systems.

It is an optional card for use when the four relays on the IOC4T I/O card are insufficient for the application and additional relays are required.

The RLC16 is mounted on the rear of the VM600 (ABE04x) rack and connects directly to the rack backplane via a connector.

The RLC16 contains 16 relays with changeover contacts. Each relay is associated with 3 terminals on the screw terminal strip at the rear of the VM600 rack.

The relays are controlled by software-controlled open collector www.ge-drive.com actuators.Jumpers on the RLC16 card allow selection of either Normal Energized (NE) or Normal De-energized (NDE) relays.

Relay Characteristics

Relay Name: RL1 to RL16

Type: PE014005

Contact Arrangement: 1 COM, 1 NC, and 1 NO contact/relay.

All relay contacts are on J1. J2 and J3.

Rated voltage: 250 VAC

Current Rating: 5 AAC

Maximum breaking capacity (no contact protection): 1250 VA

Maximum DC Load Breaking Capacity Curve

Operate/Release/Return Time: Typically 8 / 8 / 6 milliseconds

Dielectric strength test voltage

– Between open contacts: 1000 VAC

– Between contacts and coil: 4000 VAC

Mechanical life: 15 x 106 operations

Electrical life: >105 operations

Display: 16 relay PCBs

Relay status: Normal energized or normal de-energized (jumper optional)

External connections : Screw terminal connectors (J1. J2 and J3)

Mounting: Mounted on the rear of the VM600 rack and connected to the rack’s backplane via connectors. Rack Backplane

Temperature Range: See Relay Characteristics above

Humidity: ≤95% (non-condensing relative humidity)

RLC16 Power Supply

Supply voltage: +5 VDC

Consumption: 40 mA x 16 (per relay)

ENVIRONMENT

Operating environment

– Temperature : -25 to +65°C (-13 to +149°F)

– Humidity: 0 to 90% non-condensing

Storage

– Temperature : -40 to +85°C (-40 to +185°F) -40 to +85°C (-40 to +185°F)

– Humidity: 0 to 95% non-condensing

Vibration and shock: See general specifications for VM600 racks

Physical Dimensions

Height: 6U (262 mm, 10.3 inches)

Width: 20 mm (0.8 in)

Depth: 125 mm (4.9 in)

Weight: 0.30 kg (0.66 lbs)

Translated with DeepL.com (free version)

Search for products

Back to Top
Product has been added to your cart